Download Pentair SUPERFLO VST Installation And User Manual. Pentair SUPERFLO VST: Installation And User Manual | Brand: Pentair | Category: Water Pump | Size: 5.92 MB | Pages: 28. This manual is also suitable for: Superflo vs, Sta-rite supermax vs .To unscrew the impeller from the shaft, twist the impeller counter-clockwise. Remove the four bolts from the seal plate to the motor using a 9/16 inch wrench. Place the seal plate face down on a flat surface and tap out the ceramic seal. Clean the seal plate, seal housing, and the motor shaft. DO NOT run the pump dry.May 5, 2020 · I show how to program and change pump speeds one the SuperFlo VS pump. From https://www.swimmingpoolsteve.com/pages/superpump-superflo.html - See how the Pentair SuperFlo VS (342001) and the Hayward Super Pump VS (SP2603VSP) com...The SuperFlo VS is the only variable speed pump on the market today with 115/208-230V and 50/60 Hz single phase capability. The SuperFlo VS comes with a simple, easy-to-use digital control keypad, with three programmable speeds and override capability. The Pentair SuperFlo VS Pump is a medium sized head pump, manufactured with 1.5" plumbing and ...

Pentair is an equal opportunity employer. pumps • filters • heaters • heat pumps • automation • lighting • cleaners • sanitizers • water features • maintenance products Find out why SuperFlo® VS pumps are the smart PERFORMANCE CURVES upgrade for everyday pools. Learn more from your Pentair dealer or visit pentairpool.com ...The SuperFlo VS pump comes with an advanced onboard digital display and a real-time, 24-hour clock that makes everything easy to program and monitor. Select from three programmable speed settings plus an override speed setting to meet your specific pool pump needs. ... ENERGY STAR® Certified SuperFlo VS pumps from Pentair meetPosted September 28, 2010. I noticed yesterday that my 3 season-old, 1.5HP Pentair SuperFlo occasionally turns off, then re-starts during it programmed run time in auto mode (I have an EasyTouch control panel). I can't say how long it has been cycling but I've noticed it twice in the last 90 mins or so. The pump re-started within a minute or so ...

The Pentair SuperFlo 342001 is the entry level variable speed pump from Pentair. This VS pump is specifically made to compete with the Hayward SP2603VSP variable speed pump. It is the same height and length as the very popular Hayward Super Pump design so it requires zero customization to the plumbing to switch your Super Pump out for one of …The SuperFlo VS is the only variable speed pump on the market today with 115/208-230V and 50/60 Hz single phase capability. The SuperFlo VS comes with a simple, easy-to-use digital control keypad, with three programmable speeds and override capability. The Pentair SuperFlo VS Pump is a medium sized head pump, manufactured with 1.5" plumbing and ...

A properly installed and secured ANSI/ASME A112.19.8 approved anti-entrapment suction cover must be used for each drain. Each suction cover must be installed at least three …Now that you have a better idea about what your 24 hour filtration schedule should look like, and why you should program your high speed and medium speed running cycles to fall during off-peak hours, we can look at how to …Nov 29, 2023 · Conclusion: Why Pentair SuperFlo VS Stands Out. In conclusion, the Pentair SuperFlo VS is a top choice for pool owners seeking a balance of performance, efficiency, and ease of use. Its customizable settings, energy-saving features, and robust design make it a standout product in the world of pool pumps. View and Download Pentair WHISPERFLOXF VS installation and user manual online. COMMERCIAL VARIABLE SPEED PUMP. WHISPERFLOXF VS water pump pdf manual download. ... TECHNICAL DATA Performance Curves QUICK CLEAN 3450 RPM PROGRAM 3 3000 RPM PROGRAM 2 2500 RPM PROGRAM 1 1720 RPM 100 110 120 …Photo by Sarah Schorer. Step-by-Step Guide to Programming Your Pentair SuperFlo VS. Setting the Clock: Your First Step. The first step in programming your …

The pool pump is the heart of your pool’s circulatory system. It pulls water from the pool and pushes it to other equipment to be heated, treated, and filtered, returning cleaner, healthier, and warmer pool water. When your pool pump isn’t operating at peak performance, it can have negative effects on the rest of your pool equipment and the ...

Page 14 13. Stand clear of the filter. Start the pump. 14. Bleed air from the filter until a steady stream of water comes out. Close the manual air relief valve. CLAMP O-RING BASKET VOLUTE CLAMP VOLUTE Figure 4. Figure 3. SuperFlo Pump Installation and User’s Guide ®...

From http://www.swimmingpoolsteve.com/pages/superpump-superflo.html this is a quick review of the features and function of the 342001 Pentair SuperFlo VS pum...When it comes to ensuring the quality and safety of your drinking water, a reliable water filter is essential. Pentair, a trusted name in the industry, offers a range of water filt...minimum of 9.8' (3 m) from the inside wall of the pool. Install the pump a minimum of 3' (0.9 m) from the heater outlet. Do not install the pump more than 10' (3.1 m) above the water level. Install the pump in a well ventilated location protected from excess moisture (i.e. rain gutter downspouts, sprinklers, etc.).Page 1 SUPERFLO ® HIGH PERFORMANCE PUMP INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...; Page 2: Table Of Contents CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions about ordering Pentair Aquatic Systems …

Pentair 342001 SuperFlo VS Pump Drive Only For 353127 NO Keypad 353123 KCCA0192-0002. If you are Unsure which drive your SupeFlo VS Pump takes, remove the keypad cover and check the KCCC number on the drive portion. 353127 drive kit has KCCA0192-0002 and 356279 drive kit has KCCA0348-P2-G11 on it. Installing the Pentair SuperFlo VS 353127 Drive ... This item qualifies for free shipping! SuperFlo Variable Speed pumps slash energy costs by up to 80%, compared to conventional pool pumps. With premium features like a 24-hour real-time clock and an intuitive interface that displays watts and RPMs, they're easy to program and operate. With the SuperFlo VS pump, you can.Generally, the steps to program your Pentair pool pump are as follows: 1. From your pool equipment panel, locate the timer settings. This will give you the current settings on your pool pump. 2. Consult your Pentair instruction manual to determine the type of timer your pump uses, as this will vary based on model. 3.Using a 9/16" wrench, secure the seal plate to the motor with the four (4) motor bolts. Tighten to 75-80 in-lbs. (86-92 kg/cm). Hold the motor shaft in place at the rear of the motor and hand tighten the impeller clockwise onto the motor shaft. Continue to hold the motor shaft in place and reinstall the impeller screw.From https://www.swimmingpoolsteve.com/pages/superpump-superflo.html - See how the Pentair SuperFlo VS (342001) and the Hayward Super Pump VS (SP2603VSP) com...Installing and plumbing in the Pentair SuperFlo VS pump is not very difficult. But Pentair will not honor the 2 year warranty and will void the warranty unle...

HowStuffWorks shows you how to uninstall programs from Windows 10, 7, 8 and XP. Advertisement Removing an application from a Windows computer takes more than dragging and dropping ...The SuperFlo VST Pump is the superior drop-in replacement for the Hayward® Super Pump® and existing Pentair SuperFlo Pumps. 230V: WEF 9.0 THP 2.2 Display shows energy usage and other key operational information. Wiring compartment is easy to access. Built-in, real-time, 24-hour clock Intuitive, easy-to-use interface SIMPLE TO PROGRAM

The coronavirus pandemic has impacted the economy of Delaware, but there are relief programs to help struggling individuals and small businesses... Calculators Helpful Guides Compa...How To Program Pentair Pool Pump To Run Continuously. Pumps cannot technically run 24/7 because the pump needs at least a minute to reset—so they can run for 23 hours and 59 minutes. It is pretty close to 24 hours, and you will still get an all-day cleaning. It is recommended to put the schedule on either speed between 5-8 so speeds …These codes are a great way to do a simple diagnostic to see what issues your pump is having. Decoding the errors on your pump. 21- Communication link between HMI and motor control has been lost. 21 – Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the …How to program and setup a superflo pumpPentair superflo 340038 1 hp 115 230v high performance inground poolHow to program a pentair superflo vs pump or sta-rite supermax vs pump . Check Details Check Details. Amazon.com : Pentair 340039 SuperFlo High Performance Single Speed Pool. …Jul 21, 2020 ... Surge Protection Mode For Pentair SuperFlo VS & Sta-Rite SuperMax VS Variable Speed Pool Pumps In this video I talk about the process to ...The Pentair SuperFlo VS Variable Speed Pool Pump is a powerful and energy-efficient pool pump that's designed to deliver optimal performance while keeping your energy bills low. With a 1.5 horsepower motor and advanced variable speed technology, this pump is capable of providing the perfect flow rate for your pool's needs, ensuring optimal water …

Install the pump as close to the pool or spa as possible. To reduce friction loss and improve eficiency, use short, direct suction and return piping. Install a minimum of 5 ft. (1.5 m) from the inside wall of the pool and spa. Canadian installations require a minimum of 9.8 ft. (3 m) from the inside wall of the pool.

29.8K subscribers. Subscribed. 200. 33K views 4 years ago. Pentair SUPERFLO VS pump, How to Program The SUPERFLO VS is the little brother to the Intelliflo with a max power output of 2...

7 Length X 5.25 Width X 5.25 Diameter. Voltage: 115 / 230 V. Warranty: 1 Year - Proof of installation by a licensed technician is required for valid warranty coverage. Features. Variable speed technology moves water more efficiently at lower speeds. Ideal for standard pools requiring up to a 1.5 HP pump. Affordable for new and standard pump ...Photo by Sarah Schorer. Step-by-Step Guide to Programming Your Pentair SuperFlo VS. Setting the Clock: Your First Step. The first step in programming your …We would like to show you a description here but the site won’t allow us.The IntelliSync Pump Control and Monitoring System gives you smart device control of Pentair pumps such as IntelliFlo® and SuperFlo® Variable Speed Pumps. Through the convenience of the Pentair Home app, this pool pump controller* lets you adjust your pump, plus get monitoring alerts on select models. Affordable pool automation: a smart ...Claim Rebate. *Savings based on variable speed pump compared to a single-speed pump running 12 hours per day at an average of $0.16 per kWh in a 20,000 gallon pool. Actual savings may vary based on local utility rates, pool size, pump run time, pump horsepower, pump rpm, plumbing size and length, pump model, service factor and other hydraulic ...A standard efficiency Superflo 3/4 hp full rated motor running 4 hours a day with plumbing curve A and with $0.12 per kWh will cost $16.26 per month to run. For a four month season, that is $65.04 per year. Assuming an 8 percent savings, that is $5.20 saved per year by getting an energy efficient motor. The best price I see for Pentair Superflo ...Page 14 13. Stand clear of the filter. Start the pump. 14. Bleed air from the filter until a steady stream of water comes out. Close the manual air relief valve. CLAMP O-RING BASKET VOLUTE CLAMP VOLUTE Figure 4. Figure 3. SuperFlo Pump Installation and User’s Guide ®...The WhisperFlo ® VST Variable Speed Pool Pump is available now to keep pools running smoothly. This durable pump offers more power than SuperFlo ® VST Pool Pump. And your energy bill will appreciate the upgrade, too. Variable speed technology for great energy savings. Superior, drop-in replacement for existing Pentair WhisperFlo pumps.

Variable speed model from the Pentair Superflo VS pump series. Ideal for standard pools requiring up to 1.5 hp pump. Quick to program and operate with easy to understand interface. Runs on 115 or 230 volts so no rewiring needed. 3 operating speeds with operating speed range from 300 to 3450 RPM. NSF and UL-C, US certified.http://www.swimmingpoolsteve.com/pages/program-superflo.html - See a demonstration of how to change the RPM speed for the Quick Clean setting on the Pentair ...4 – 4:30 a.m. High speed (3450 RPMs to ensure the pump sufficiently primes- non-peak hours) 4:30 – 12 p.m. Mid speed (2200 RPMs- non-peak hours) 12 p.m. – 6 p.m. Low speed (1800 RPMS- peak hours) The total run time is 14 hours. I run my pump this long because I live in Florida and it is consistently hot. In colder states, you probably ...353134S 1.5 HP Variable Speed VS TEFC Motor for Pentair 342001 SuperFlo VS 353132 Swimming Pool Pump made by Pentair. If you’re not sure which motor to choose for your Pentair SuperFlo Variable Speed Pump, please refer to the image and examine the plug shown in the close-up view. The SuperFlo Variable Speed Pumps are available with two …Instagram:https://instagram. gus thornhill funeral home facebookrock and roll lounge bar rescuehendrix bbq statesville blvdbroward county tags and titles About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... publix hours miami flfreaky pics memes minimum of 9.8' (3 m) from the inside wall of the pool. Install the pump a minimum of 3' (0.9 m) from the heater outlet. Do not install the pump more than 10' (3.1 m) above the water level. Install the pump in a well ventilated location protected from excess moisture (i.e. rain gutter downspouts, sprinklers, etc.).These codes are a great way to do a simple diagnostic to see what issues your pump is having. Decoding the errors on your pump. 21- Communication link between HMI and motor control has been lost. 21 – Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the … lmu spring 2024 calendar Detailed instructions on how to replace a pool pump seal for a Pentair SuperFlo® & SuperMax® swimming pool pump using a Pentair Genuine pump seal Quick-Kit. ...Pentair WhisperFlo 011518 Single Speed Pump having one standard speed, 1.5 HP, a solid business-grade, substantial 56 edge engine that needs no grease. The pump additionally can change itself to the current. Yet, Pentair SuperFlo and WisperFlo contrast in commotion level. Along these lines, this unit includes an extraordinary … Install the pump as close to the pool or spa as possible. To reduce friction loss and improve eficiency, use short, direct suction and return piping. Install a minimum of 5 ft. (1.5 m) from the inside wall of the pool and spa. Canadian installations require a minimum of 9.8 ft. (3 m) from the inside wall of the pool.